150
The temperature control unit for oil up to 150 °C and water up to 90 °C
- Control system RT200
- Pump with high flow rate: 70 l/min
- High cooling capacity
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
Oil
90
°C
150
°C
6 / 12 / 18
kW
6 / 12
kW
140
°C
140
°C
58
kW
75
kW
TP20
TS22
60
l/min
70
l/min
0.5
kW
0.92
kW
Technical data
more
less
Outlet temperature |
|
|||
max. | °C |
|
||
Heat transfer medium |
|
|||
Filling quantity | l |
|
||
Expansion volume | l |
|
||
Heating capacity at 400V | kW |
|
||
Cooling capacity | kW |
|
||
Cooler |
|
|||
at outlet temperature | °C |
|
||
at cooling water temperature | °C |
|
||
Pump capacity/Type |
|
|||
Flow rate max. | l/min |
|
||
Power consumption | kW |
|
||
Pressure max. | bar |
|
||
Control system | RT100 / RT200 | |||
Measuring mode (standard) | Pt100 | |||
Operating voltage | V/Hz | 200-600 V, 50/60 Hz | ||
Connections | ||||
Outlet/Inlet | G3/4" | |||
Cooling water mains | G1/2" | |||
Degree of protection | IP40 | |||
Dimensions W/H/D | mm | 346/690/728 | ||
Weight | kg | 78 | ||
Color | RAL | 7035/7024 | ||
Ambient temperature | ||||
max. | °C | 40 | ||
Noise level | db (A) | < 70 |
Standard equipment
more
less
- Filter in cooling water circuit
- Leak-free pump
- Water circuit of non-rusting materials
- Solid-state relay (SSR) instead of heating contactor
- RT200 control system
Pump curve
more
less
Cooling curve
more
less