P100S

P100S

Pressurised-water temperature control unit up to 100 °C

  • Control system RT200
  • Pump with high flow rate: 40 l/min
  • Pressure control
  • Leak-free pump with magnetic coupling
  • Solid-state relay instead of heating contactor
Technical specifications more less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
100 °C
8 kW
90 °C
90 °C
90 °C
145 kW
60 kW
78 kW
SM22
PM23
40 l/min
50 l/min
0.5 kW
1.4 kW
Technical data
Outlet temperature  
max. °C 100
Heat transfer medium   Water
Filling quantity l 1.0
Expansion volume l -
Heating capacity at 400V kW 8
Cooling capacity kW
145 60 78
Cooler
DK 1K 2K
at outlet temperature °C
90 90 90
at cooling water temperature °C
20 20 20
Pump capacity/Type
SM22 PM23
Flow rate max. l/min
40 50
Power consumption kW
0.5 1.4
Pressure max. bar
5.0 9.0
Control system   RT100 / RT200
Measuring mode (standard)   Pt100
Operating voltage V/Hz 200-600 V, 50/60 Hz
Connections  
Outlet/Inlet   G1/2"
Cooling water mains   G1/2"
Degree of protection   IP54
Dimensions W/H/D mm 232/589/812
Weight kg 50
Color RAL 9006/7016
Ambient temperature  
max. °C 40
Noise level db (A) < 70
Standard equipment
  • Solid-state relay (SSR) instead of heating contactor
  • Filter in the main circuit
  • Automatic water refill
  • Leak-free pump
  • Direct cooling (DK)
  • Unit in IP54 protection degree
  • RT200 control system
Options
  • Electronic flow measurement
  • Hand valve in inlet and outlet
  • Indirect cooling
  • Cleanroom version
  • Pump PM23 only with frequency converter
  • RT100 control system
Pump curve
Cooling curve