P120smart
Temperature control unit for water up to 120 °C
- RT70 control system with 3.5" TFT display
- Pump with high flow rate: 105 l/min / 125 l/min
- Heating capacity: 8kW (400V) EU standard / 10 kW (480V) US standard
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
120
°C
8
kW
(480V) 10
kW
110
°C
160
kW
CM 5-4
CM 5-3
105
l/min
125
l/min
1.1
kW
1.1
kW
Technical data
more
less
| Outlet temperature | ||||
| max. | 120 | °C | ||
| Heat transfer medium | Water | |||
| Filling quantity | 3.0 | l | ||
| Expansion volume | - | l | ||
| Heating capacity at 400V | 8 | kW | ||
| Heating capacity at 480V | (480V) 10 | kW | ||
| Cooling capacity | 160 | kW | ||
| Cooler | DK | |||
| at outlet temperature | 110 | °C | ||
| at cooling water temperature | 20 | °C | ||
| Pump capacity/Type |
|
|||
| Flow rate max. |
|
l/min | ||
| Power consumption |
|
kW | ||
| Pressure max. |
|
bar | ||
| Control system | RT70 | |||
| Measuring mode (standard) | Pt100 | |||
| Operating voltage |
|
V/Hz | ||
| Connections | ||||
| Outlet/Inlet | G1" | |||
| Cooling water mains | G3/4" | |||
| Degree of protection | IP40 | |||
| Dimensions W/H/D | 240/600/644 | mm | ||
| Weight | 40 | kg | ||
| Color | 9006/7043 | RAL | ||
| Ambient temperature | ||||
| max. | 40 | °C | ||
| Noise level | < 70 | db (A) |
Standard equipment
more
less
- RT70 control system with 3.5" TFT display
- Solid-state relay (SSR) instead of heating contactor
- Filter in the main circuit
- Automatic water refill
- Direct cooling (DK)
- Unit in IP40 protection degree