P140XS

P140XS

The P140XS is equipped with proven REGLOPLAS technology and with all the advantages of the REGLOPLAS large unit series, in the temperature range up to 140 °C medium temperature.

  • Control system RT200
  • Pump with high flow rate: 11 l/min
  • Low-scaling cooling system "SK"
Technical specifications more less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
140 °C
3 kW
130 °C
38 kW
SG14
11 l/min
0.14 kW
Technical data
Outlet temperature  
max. °C 140
Heat transfer medium   Water
Filling quantity l 0.5
Expansion volume l -
Heating capacity at 400V kW 3
Cooling capacity kW 38
Cooler   1K
at outlet temperature °C 130
at cooling water temperature °C 20
Pump capacity/Type   SG14
Flow rate max. l/min 11
Power consumption kW 0.14
Pressure max. bar 3.7
Control system   RT100 / RT200
Measuring mode (standard)   Pt100
Operating voltage V/Hz 400 V, 50 Hz, 3 PE
Connections  
Outlet/Inlet   G3/8"
Cooling water mains   G1/4"
Degree of protection   IP54
Dimensions W/H/D mm 143/420/520
Weight kg 25
Color RAL 9006
Ambient temperature  
max. °C 40
Noise level db (A) < 70
Standard equipment
  • Filter in the main circuit
  • Filter in cooling water circuit
  • Leak-free pump
  • Water circuit of non-rusting materials
  • Automatic water refill
  • Solid-state relay (SSR) instead of heating contactor
  • Unit in IP54 protection degree
  • Indirect cooling (1K)
  • RT200 control system
Options
  • Electronic flow measurement
  • Hand valve in inlet and outlet
  • RT100 control system
Pump curve
Cooling curve