P200XL-V25

Pressurized-water temperature control unit up to 200 °C
- Control system RT200
- Pump with high flow rate: 200 l/min
- Low-scale cooling system "SK"
- Pressure control
- Solid-state relay instead of heating contactor
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
200
°C
20 / 40 / 60 / 80 / 100
kW
190
°C
500
kW
PMK300
PMK500
300
l/min
500
l/min
2.8
kW
5.3
kW
Technical data
more
less
Outlet temperature | ||||
max. | °C | 200 | ||
Heat transfer medium | Water | |||
Filling quantity | l | 35.0 | ||
Expansion volume | l | 10 | ||
Heat transfer medium | Water | |||
Filling quantity | l | 35.0 | ||
Expansion volume | l | 10 | ||
Heating capacity at 400V | kW | 20 / 40 / 60 / 80 / 100 | ||
Cooling capacity | kW | 500 | ||
Cooler | SK3 | |||
at outlet temperature | °C | 190 | ||
at cooling water temperature | 20 with >100l/min | |||
Pump capacity/Type |
|
|||
Flow rate max. | l/min |
|
||
Power consumption | kW |
|
||
Pressure max. | bar |
|
||
Control system | RT200 | |||
Measuring mode (standard) | Pt100 | |||
Operating voltage | V/Hz | 200-600 V, 50/60 Hz | ||
Connections | ||||
Outlet/Inlet | G2" 60°Cone | |||
Cooling water mains | G3/4" | |||
Degree of protection | IP54 | |||
Dimensions W/H/D | mm | 430/1302/1350 | ||
Weight | kg | 265 | ||
Color | RAL | 7035/7042/7043 | ||
Ambient temperature | ||||
max. | °C | 40 | ||
Noise level | db (A) | < 70 |
Standard equipment
more
less
- Solid-state relay (SSR) instead of heating contactor
- Integrated status light
- Water circuit of non-rusting materials
- Automatic water refill
- In- and Outlet PT100 sensor
- Filter in cooling water circuit 300um
- Leakage monitoring
- Motors IE3 standard
- Pump PMK300 and PMK500 with frequency converter
- Patented low-scale cooling system (SK)
- Safety pressure valve
- Safety thermostat
- Pressure drain
- Pressure gauge outlet
- Pressure gauge for system pressure
- Active pressure relief system
- Unit in IP54 protection degree
- RT200 control system
Principle Scheme*
more
less