P200XLcalidra
Compact water temperature control unit with fresh design and high performant capabilities
- Control system RT200
- Pump with high flow rate up to 500 l/min
- Low-scale cooling system 2SK / 3SK
- Pressure control
- Solid-state relay instead of heating contactor
- Cyclone separator for enhanced filtretion
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
200
°C
40 / 100
kW
190
°C
500
kW
PM300
PM500
300
l/min
500
l/min
2.8
kW
5.3
kW
Technical data
more
less
| Outlet temperature | ||||
| max. | 200 | °C | ||
| Heat transfer medium | Water | |||
| Filling quantity | max. 35 | l | ||
| Expansion volume | 10 | l | ||
| Heating capacity at 400V | 40 / 100 | kW | ||
| Cooling capacity | 500 | kW | ||
| Cooler | 2SK / 3SK | |||
| at outlet temperature | 190 | °C | ||
| at cooling water temperature | 2SK > 50l/min, 3SK > 90l/min | |||
| Pump capacity/Type |
|
|||
| Flow rate max. |
|
l/min | ||
| Power consumption |
|
kW | ||
| Pressure max. |
|
bar | ||
| Control system | RT200 | |||
| Measuring mode (standard) | Pt100 | |||
| Operating voltage | 3 x 400 V, 50/60 Hz | V/Hz | ||
| Connections | ||||
| Outlet/Inlet | DN 50 (G2" 60°Cone) | |||
| Cooling water mains | SK / 2SK: G 1/2", 3SK: G3/4" | |||
| Degree of protection | IP54 | |||
| Dimensions W/H/D | 430/1300/1356 | mm | ||
| Weight | 250-300 | kg | ||
| Color | 7035/7042/7043 | RAL | ||
| Ambient temperature | ||||
| max. | 40 | °C | ||
| Noise level | < 70 | db (A) |
Standard equipment
more
less
- RT200 control system
- Solid-state relay (SSR) instead of heating contactor
- Integrated status light
- Water circuit of non-rusting materials
- Automatic water refill
- In- and Outlet Pt100 sensor
- Filter in cooling water circuit 300um
- Motors IE3 standard
- Pump PMK300 and PMK500 with frequency converter
- Low-scale cooling system (SK)
- Safety pressure release valve
- Safety thermostat
- Pressure drain
- Pressure gauge outlet
- Pressure gauge for system pressure
- Active pressure release system
- Unit in IP54 protection degree