P230S

Pressurised-water temperature control unit up to 230 °C
- Control system RT200
- Pump with high flow rate: 40 l/min
- Low-scaling cooling system "SK"
- Patented heater pressure stabaliser
- Pressure control
- Leak-free pump with magnetic coupling
- Solid-state relay instead of heating contactor
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
230
°C
8
kW
220
°C
88
kW
PM23H
50
l/min
1.4
kW
Technical data
more
less
Outlet temperature | ||
max. | °C | 230 |
Heat transfer medium | Water | |
Filling quantity | l | 1.5 |
Expansion volume | l | - |
Heating capacity at 400V | kW | 8 |
Cooling capacity | kW | 88 |
Cooler | SK | |
at outlet temperature | °C | 220 |
at cooling water temperature | °C | 20 |
Pump capacity/Type | PM23H | |
Flow rate max. | l/min | 50 |
Power consumption | kW | 1.4 |
Pressure max. | bar | 9.0 |
Control system | RT100 / RT200 | |
Measuring mode (standard) | Pt100 | |
Operating voltage | V/Hz | 200-600 V, 50/60 Hz |
Connections | ||
Outlet/Inlet | G1/2" /SAE1" | |
Cooling water mains | G1/2" | |
Degree of protection | IP54 | |
Dimensions W/H/D | mm | 297/711/971 |
Weight | kg | 90 |
Color | RAL | 9006/7016 |
Ambient temperature | ||
max. | °C | 40 |
Noise level | db (A) | < 70 |
Standard equipment
more
less
- Patented pressure holder
- Solid-state relay (SSR) instead of heating contactor
- Filter in the main circuit
- Draining the consumer by suction
- Leak-free pump
- Pump PM23H only with frequency converter
- Patented low-scale cooling system (SK)
- Unit in IP54 protection degree
- RT200 control system
Pump curve
more
less

Cooling curve
more
less