150
The temperature control unit for oil up to 150 °C and water up to 90 °C
- Control system RT200
- Pump with high flow rate: 70 l/min
- High cooling capacity
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
Oil
90
°C
150
°C
6 / 12 / 18
kW
6 / 12
kW
80/140
°C
80/140
°C
58
kW
75
kW
TP20
TS22
60
l/min
70
l/min
0.5
kW
0.92
kW
Technical data
more
less
| Outlet temperature |
|
|||
| max. |
|
°C | ||
| Heat transfer fluids Groups |
|
|||
| Filling quantity |
|
l | ||
| Expansion volume |
|
l | ||
| Heating capacity at 400V |
|
kW | ||
| Cooling capacity |
|
kW | ||
| Cooler |
|
|||
| at outlet temperature |
|
°C | ||
| at cooling water temperature |
|
°C | ||
| Pump capacity/Type |
|
|||
| Flow rate max. |
|
l/min | ||
| Power consumption |
|
kW | ||
| Pressure max. |
|
bar | ||
| Control system | RT100 / RT200 | |||
| Measuring mode (standard) | Pt100 | |||
| Operating voltage | 3 x 400 V, 50/60 Hz | V/Hz | ||
| Connections | ||||
| Outlet/Inlet | G3/4" | |||
| Cooling water mains | G1/2" | |||
| Degree of protection | IP40 | |||
| Dimensions W/H/D | 346/690/728 | mm | ||
| Weight | 78 | kg | ||
| Color | 7035/7024 | RAL | ||
| Ambient temperature | ||||
| max. | 40 | °C | ||
| Noise level | < 70 | db (A) |
Standard equipment
more
less
- Filter in cooling water circuit
- Leak-free pump
- Water circuit of non-rusting materials
- Solid-state relay (SSR) instead of heating contactor
- RT200 control system
Pump curve
more
less

Cooling curve
more
less