150S up to 180 °C
The temperature control unit for oil up to 180 °C
- Control system RT200
- Immersion pump with high flow rate: 70 l/min
- Solid-state relay instead of heating contactor
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Oil
180
°C
6 / 9
kW
80/140
°C
29
kW
Technical data
more
less
| Heat transfer medium | Oil | |
| Filling quantity | 7.5 | l |
| Expansion volume | 4.5 | l |
| Outlet temperature | ||
| max. (Oil) | 180 | °C |
| Heating capacity at 400V | 6 / 9 | kW |
| Cooling capacity | 29 | kW |
| Cooler | 1K | |
| at outlet temperature | 80/140 | °C |
| at cooling water temperature | 20 | °C |
| Pump capacity/Type | TS22H | |
| Flow rate max. | 70 | l/min |
| Power consumption | 0.92 | kW |
| Pressure max. | 5.4 | bar |
| Control system | RT100 / RT200 | |
| Measuring mode (standard) | Pt100 | |
| Operating voltage | 3 x 400 V, 50/60 Hz | V/Hz |
| Connections | ||
| Outlet/Inlet | G1/2" | |
| Cooling water mains | G1/2" | |
| Degree of protection | IP40 | |
| Dimensions W/H/D | 202/560/732 | mm |
| Weight | 50 | kg |
| Color | 9006/7016 | RAL |
| Ambient temperature | ||
| max. | 40 | °C |
| Noise level | < 70 | db (A) |
Standard equipment
more
less
- Solid-state relay (SSR) instead of heating contactor
- Immersion pump
- Indirect cooling
- Filler neck
- Filter in cooling water circuit
- Draining the consumer by suction
- Unit in IP40 protection degree
- RT200 control system
Pump curve
more
less

Cooling curve
more