300LD
The dual-zone temperature control unit for thermal oil up to 300 °C
- Control system RT200
- High heating capacity max. 80 kW (2 x 40 kW)
- Pump with high flow rate: 90 l/min per circle
- Leak-free pump with magnetic coupling
- Solid-state relay instead of heating contactor
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Oil
300
°C
10 / 17.5 / 20 / 30 / 40
kW
280
°C
160
kW
FM65
90
l/min
2.8
kW
Technical data
more
less
Outlet temperature | ||
max. | °C | 300 |
Heat transfer medium | Oil | |
Filling quantity | l | 24.0 |
Expansion volume | l | 20.0 |
Heating capacity at 400V | kW | 10 / 17.5 / 20 / 30 / 40 |
Cooling capacity | kW | 160 |
Cooler | 1K | |
at outlet temperature | °C | 280 |
at cooling water temperature | °C | 20 |
Pump capacity/Type | FM65 | |
Flow rate max. | l/min | 90 |
Power consumption | kW | 2.8 |
Pressure max. | bar | 9.5 |
Control system | RT100 / RT200 | |
Measuring mode (standard) | Pt100 | |
Operating voltage | V/Hz | 200-600 V, 50/60 Hz |
Connections | ||
Outlet/Inlet | G3/4" IG | |
Cooling water mains | G3/4" | |
Degree of protection | IP54 | |
Dimensions W/H/D | mm | 542/1351/1474 |
Weight | kg | 365 |
Color | RAL | 9006/7016 |
Ambient temperature | ||
max. | °C | 40 |
Noise level | db (A) | < 70 |
Standard equipment
more
less
- Solid-state relay (SSR) instead of heating contactor
- Unit in IP54 protection degree
- Second level
- Leak-free pump
- Filter in the main circuit
- Filter in cooling water circuit
- Water circuit of non-rusting materials
- Pressure gauge outlet
- Pressure gauge inlet
- RT200 control system
Pump curve
more
less
Cooling curve
more
less