300LD

300LD

The dual-zone temperature control unit for thermal oil up to 300 °C

  • Control system RT200
  • High heating capacity max. 80 kW (2 x 40 kW)
  • Pump with high flow rate: 90 l/min per circle
  • Leak-free pump with magnetic coupling
  • Solid-state relay instead of heating contactor 
Technical specifications more less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Oil
300 °C
10 / 17.5 / 20 / 30 / 40 kW
280 °C
160 kW
FM65
90 l/min
2.8 kW
Technical data
Outlet temperature  
max. °C 300
Heat transfer medium   Oil
Filling quantity l 24.0
Expansion volume l 20.0
Heating capacity at 400V kW 10 / 17.5 / 20 / 30 / 40
Cooling capacity kW 160
Cooler   1K
at outlet temperature °C 280
at cooling water temperature °C 20
Pump capacity/Type   FM65
Flow rate max. l/min 90
Power consumption kW 2.8
Pressure max. bar 9.5
Control system   RT100 / RT200
Measuring mode (standard)   Pt100
Operating voltage V/Hz 200-600 V, 50/60 Hz
Connections  
Outlet/Inlet   G3/4" IG
Cooling water mains   G3/4"
Degree of protection   IP54
Dimensions W/H/D mm 542/1351/1474
Weight kg 365
Color RAL 9006/7016
Ambient temperature  
max. °C 40
Noise level db (A) < 70
Standard equipment
  • Solid-state relay (SSR) instead of heating contactor
  • Unit in IP54 protection degree
  • Second level
  • Leak-free pump
  • Filter in the main circuit
  • Filter in cooling water circuit
  • Water circuit of non-rusting materials
  • Pressure gauge outlet
  • Pressure gauge inlet
  • RT200 control system
Options
  • Cooler with bypass circuit
  • Electronic flow measurement
  • Optional with second RT100 control system
  • Optional with RT200 control system
  • RT100 control system
Pump curve
Cooling curve