300LD

300LD

The dual-zone temperature control unit for thermal oil up to 300 °C

  • Control system RT200
  • High heating capacity max. 80 kW (2 x 40 kW)
  • Pump with high flow rate: 90 l/min per circle
  • Leak-free pump with magnetic coupling
  • Solid-state relay instead of heating contactor 
Technical specifications more less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Oil
300 °C
10 / 17.5 / 20 / 30 / 40 kW
280 °C
160 kW
FM65
90 l/min
2.8 kW
Technical data
Outlet temperature  
max. 300 °C
Heat transfer medium Oil  
Filling quantity 24.0 l
Expansion volume 20.0 l
Heating capacity at 400V 10 / 17.5 / 20 / 30 / 40 kW
Cooling capacity 160 kW
Cooler 1K  
at outlet temperature 280 °C
at cooling water temperature 20 °C
Pump capacity/Type FM65  
Flow rate max. 90 l/min
Power consumption 2.8 kW
Pressure max. 9.5 bar
Control system RT100 / RT200  
Measuring mode (standard) Pt100  
Operating voltage 3 x 400 V, 50/60 Hz V/Hz
Connections  
Outlet/Inlet G3/4" IG  
Cooling water mains SK / 2SK: G 1/2", 3SK: G3/4"  
Degree of protection IP54  
Dimensions W/H/D 542/1351/1474 mm
Weight 365 kg
Color 9006/7016 RAL
Ambient temperature  
max. 40 °C
Noise level < 70 db (A)
Standard equipment
  • Solid-state relay (SSR) instead of heating contactor
  • Unit in IP54 protection degree
  • Second level
  • Leak-free pump
  • Filter in the main circuit
  • Filter in cooling water circuit
  • Water circuit of non-rusting materials
  • Pressure gauge outlet
  • Pressure gauge inlet
  • RT200 control system
Options
  • Cooler with bypass circuit
  • Electronic flow measurement
  • Optional with second RT100 control system
  • Optional with RT200 control system
  • RT100 control system