300MD
The dual-zone temperature control unit for thermal oil up to 300 °C
- Control system RT200
- Heating capacity 24 kW (2 x 12 kW)
- Pump with high flow rate: 80 l/min
- Leak-free pump with magnetic coupling
- Electronic pressure display
- Solid-state relay instead of heating contactor
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Oil
300
°C
12
kW
280
°C
130
kW
FM32
FM35
80
l/min
85
l/min
1.5
kW
2.2
kW
Technical data
more
less
Outlet temperature | ||||
max. | °C | 300 | ||
Heat transfer medium | Oil | |||
Filling quantity | l | 22.0 | ||
Expansion volume | l | 14.0 | ||
Heating capacity at 400V | kW | 12 | ||
Cooling capacity | kW | 130 | ||
Cooler | 1K | |||
at outlet temperature | °C | 280 | ||
at cooling water temperature | °C | 20 | ||
Pump capacity/Type |
|
|||
Flow rate max. | l/min |
|
||
Power consumption | kW |
|
||
Pressure max. | bar |
|
||
Control system | RT200 | |||
Operating voltage | V/Hz | 400-480 V, 50/60 Hz | ||
Connections | ||||
Outlet/Inlet | G3/4" IG | |||
Cooling water mains | G3/4" | |||
Degree of protection | IP54 | |||
Dimensions W/H/D | mm | 407/1150/1349 | ||
Weight | kg | 235 | ||
Color | RAL | 9006/7016 | ||
Ambient temperature | ||||
max. | °C | 40 | ||
Noise level | db (A) | < 70 |
Standard equipment
more
less
- Solid-state relay (SSR) instead of heating contactor
- Unit in IP54 protection degree
- Second level
- Leak-free pump
- Filter in the main circuit
- Filter in cooling water circuit
- Water circuit of non-rusting materials
- Outlet pressure sensor
- RT200 control system
Pump curve
more
less
Cooling curve
more
less