P160LD

P160LD

Dual zone pressurised-water temperature control unit up to 160 °C

  • Control system RT200 with 2 seperate displays
  • Robust pump with flow rate of 80 l/min
  • Low-scaling cooling system "SK"
  • Pressure control
  • Solid-state relay instead of heating contactor
  • Heavy particle separator in the inlet
Technical specifications more less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
160 °C
17 kW
150 °C
150 °C
66 kW
78 kW
SM82
80 l/min
2.8 kW
Technical data
Outlet temperature  
max. 160 °C
Heat transfer medium Water  
Filling quantity 3.0 l
Expansion volume 2.0 l
Heating capacity at 400V 17 kW
Cooling capacity
66 78
kW
Cooler
SK 2SK
at outlet temperature
150 150
°C
at cooling water temperature
20 20
°C
Pump capacity/Type SM82  
Flow rate max. 80 l/min
Power consumption 2.8 kW
Pressure max. 9.0 bar
Control system RT100 / RT200  
Measuring mode (standard) Pt100  
Operating voltage 400 V, 50 Hz, 3 PE V/Hz
Connections  
Outlet/Inlet G3/4"  
Cooling water mains G1/2"  
Degree of protection IP54  
Dimensions W/H/D 507/1167/1492 mm
Weight 280 kg
Color 9006/7016 RAL
Ambient temperature  
max. 40 °C
Noise level < 70 db (A)
Standard equipment
  • Solid-state relay (SSR) instead of heating contactor
  • Filter in the main circuit
  • Pressure gauge for system pressure
  • Draining the consumer by suction
  • Leak-free pump
  • Patented low-scale cooling system (SK)
  • Unit in IP54 protection degree
  • RT200 control system
Options
  • Electronic flow measurement
  • Hand valve in inlet and outlet
  • Pump control
  • RT100 control system
Pump curve
Cooling curve