P160LD
Dual zone pressurised-water temperature control unit up to 160 °C
- Control system RT200 with 2 seperate displays
- Robust pump with flow rate of 80 l/min
- Low-scaling cooling system "SK"
- Pressure control
- Solid-state relay instead of heating contactor
- Heavy particle separator in the inlet
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
160
°C
17
kW
150
°C
150
°C
66
kW
78
kW
SM82
80
l/min
2.8
kW
Technical data
more
less
| Outlet temperature | ||||
| max. | 160 | °C | ||
| Heat transfer medium | Water | |||
| Filling quantity | 3.0 | l | ||
| Expansion volume | 2.0 | l | ||
| Heating capacity at 400V | 17 | kW | ||
| Cooling capacity |
|
kW | ||
| Cooler |
|
|||
| at outlet temperature |
|
°C | ||
| at cooling water temperature |
|
°C | ||
| Pump capacity/Type | SM82 | |||
| Flow rate max. | 80 | l/min | ||
| Power consumption | 2.8 | kW | ||
| Pressure max. | 9.0 | bar | ||
| Control system | RT100 / RT200 | |||
| Measuring mode (standard) | Pt100 | |||
| Operating voltage | 400 V, 50 Hz, 3 PE | V/Hz | ||
| Connections | ||||
| Outlet/Inlet | G3/4" | |||
| Cooling water mains | G1/2" | |||
| Degree of protection | IP54 | |||
| Dimensions W/H/D | 507/1167/1492 | mm | ||
| Weight | 280 | kg | ||
| Color | 9006/7016 | RAL | ||
| Ambient temperature | ||||
| max. | 40 | °C | ||
| Noise level | < 70 | db (A) |
Standard equipment
more
less
- Solid-state relay (SSR) instead of heating contactor
- Filter in the main circuit
- Pressure gauge for system pressure
- Draining the consumer by suction
- Leak-free pump
- Patented low-scale cooling system (SK)
- Unit in IP54 protection degree
- RT200 control system
Pump curve
more
less

Cooling curve
more
less