P180S eMold

P180S eMold

The efficient, energy-saving and compact pressurized-water temperature control unit with unmatched connectivity. Designed for plastic injection molding and industrial applications up to 180 °C

  • Automatic energy-saving modes (Delta-T, flow control, pressure control)
  • Most efficient, high-performance pump with variable pump speed (IE4, synchronous motor)
  • RT200 controller with modern touch interface
  • Maximum functionality and features included
  • Unmatched RT200-connectivity
  • Access through LAN, WLAN, web browser (HTML 5), TeamViewer
  • OPC UA interface standard on all units
  • Additional interface integrated
  • New ESK-cooling with variable capacity
  • Separated Cooling circuit (Low calcification, long lifetime)
  • Compact, robust, and field-proven design
Technical specifications more less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
180 °C
8 kW
170 °C
90 kW
PM23H
50 l/min
1.4 kW
Technical data
Outlet temperature  
max. °C 180
Heat transfer medium   Water
Filling quantity l 1.0
Expansion volume l -
Heating capacity at 400V kW 8
Cooling capacity kW 90
Cooler   2ESK
at outlet temperature °C 170
at cooling water temperature °C 20
Pump capacity/Type   PM23H
Flow rate max. l/min 50
Power consumption kW 1.4
Pressure max. bar 9.0
Control system   RT200
Measuring mode (standard)   Pt100
Operating voltage V/Hz 400/ 50/60
Connections  
Outlet/Inlet   G1/2"
Cooling water mains   G1/2"
Degree of protection   IP54
Dimensions W/H/D mm 235/594/812
Weight kg 50
Color   Regloplas green/9005
Ambient temperature  
max. °C 40
Noise level db (A) < 70
Standard equipment
  • Solid-state relay (SSR) instead of heating contactor
  • Filter in the main circuit
  • Automatic water refill
  • Leak-free pump with magnetic coupling
  • Low-scaling and variable cooling system
  • Direct access to control system via web-browser (HTML 5)
  • Online software-update
  • Unit in IP54 protection degree
  • RT200 control system
  • Timer (Timer function)
  • Delta-T control
  • Pressure control
  • Flow control
  • Connection cable 4m for backside unit
  • Cascade control Inlet Sn3
  • Flushing of unit
  • Set point value ramp
  • Draining the consumer by suction
  • Vapor suppression
  • Outlet pressure on Display
  • Pump condition monitoring
  • Interface OPC UA RT200 (WLAN/Ethernet)
  • Ethernet RJ45 Service Interface
  • One additional interface of your choice
  • USB data logger
Options
  • Manual valve in inlet and outlet
  • multiFlow distributor
  • Flow meter MF180 (inside)
  • Heating current monitoring
  • RT100 control system
Pump curve
Cooling curve