P180S
Pressurised-water temperature control unit up to 180 °C
- Control system RT200
- Pump with high flow rate: 40 l/min
- Low-scaling cooling system "SK"
- Pressure control
- Leak-free pump with magnetic coupling
- Solid-state relay instead of heating contactor
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
180
°C
8
kW
170
°C
170
°C
76
kW
90
kW
SM23H
PM23H
40
l/min
50
l/min
0.5
kW
1.4
kW
Technical data
more
less
| Outlet temperature | ||||
| max. | 180 | °C | ||
| Heat transfer medium | Water | |||
| Filling quantity | 1.0 | l | ||
| Expansion volume | - | l | ||
| Heating capacity at 400V | 8 | kW | ||
| Cooling capacity |
|
kW | ||
| Cooler |
|
|||
| at outlet temperature |
|
°C | ||
| at cooling water temperature |
|
°C | ||
| Pump capacity/Type |
|
|||
| Flow rate max. |
|
l/min | ||
| Power consumption |
|
kW | ||
| Pressure max. |
|
bar | ||
| Control system | RT100 / RT200 | |||
| Measuring mode (standard) | Pt100 | |||
| Operating voltage | 3 x 400 V, 50/60 Hz | V/Hz | ||
| Connections | ||||
| Outlet/Inlet | G1/2" | |||
| Cooling water mains | G1/2" | |||
| Degree of protection | IP54 | |||
| Dimensions W/H/D | 236/589/812 | mm | ||
| Weight | 52 | kg | ||
| Color | 9006/7016 | RAL | ||
| Ambient temperature | ||||
| max. | 40 | °C | ||
| Noise level | < 70 | db (A) |
Standard equipment
more
less
- Solid-state relay (SSR) instead of heating contactor
- Filter in the main circuit
- Draining the consumer by suction
- Leak-free pump
- Patented low-scale cooling system (SK)
- Unit in IP54 protection degree
- RT200 control system
Pump curve
more
less

Cooling curve
more
less