P200M
Pressurised-water temperature control unit up to 200 °C
- Control system RT200
- Pump with high flow rate: 100 l/min
- Low-scaling cooling system "SK"
- Pressure control
- Leak-free pump with magnetic coupling
- Solid-state relay instead of heating contactor
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
200
°C
8 / 18
kW
190
°C
190
°C
86
kW
102
kW
SM73H
SM75H
PM75H
60
l/min
90
l/min
85
l/min
1.0
kW
1.5
kW
2.2
kW
Technical data
more
less
| Outlet temperature | |||||
| max. | 200 | °C | |||
| Heat transfer medium | Water | ||||
| Filling quantity | max. 35 | l | |||
| Expansion volume | 10 | l | |||
| Filling quantity | 1.9 | l | |||
| Expansion volume | - | l | |||
| Heating capacity at 400V | 8 / 18 | kW | |||
| Cooling capacity |
|
kW | |||
| Cooler |
|
||||
| at outlet temperature |
|
°C | |||
| at cooling water temperature |
|
°C | |||
| Pump capacity/Type |
|
||||
| Flow rate max. |
|
l/min | |||
| Power consumption |
|
kW | |||
| Pressure max. |
|
bar | |||
| Control system | RT100 / RT200 | ||||
| Measuring mode (standard) | Pt100 | ||||
| Operating voltage | 3 x 400 V, 50/60 Hz | V/Hz | |||
| Connections | |||||
| Outlet/Inlet | G3/4" | ||||
| Cooling water mains | G1/2" | ||||
| Degree of protection | IP54 | ||||
| Dimensions W/H/D | 295/711/914 | mm | |||
| Weight | 84 | kg | |||
| Color | 9006/7016 | RAL | |||
| Ambient temperature | |||||
| max. | 40 | °C | |||
| Noise level | < 70 | db (A) |
Standard equipment
more
less
- Solid-state relay (SSR) instead of heating contactor
- Filter in the main circuit
- Draining the consumer by suction
- Leak-free pump
- Patented low-scale cooling system (SK)
- Unit in IP54 protection degree
- RT200 control system
Pump curve
more
less

Cooling curve
more