P200XL
Pressurized-water temperature control unit up to 200 °C
- Control system RT200
- Pump with high flow rate: 200 l/min
- Low-scale cooling system "SK"
- Pressure control
- Solid-state relay instead of heating contactor
Technical specifications
more
less
Heat transfer medium
Outlet temperature
Heating capacity at 400V
Cooling capacity
Pump capacity/Type
Water
200
°C
20 / 40 / 60
kW
190
°C
177
kW
SM85H
PM85H
200
l/min
200
l/min
3.5
kW
4.0
kW
Technical data
more
less
| Outlet temperature | ||||
| max. | 200 | °C | ||
| Heat transfer medium | Water | |||
| Filling quantity | 10 | l | ||
| Expansion volume | 5.0 | l | ||
| Heating capacity at 400V | 20 / 40 / 60 | kW | ||
| Cooling capacity | 177 | kW | ||
| Cooler | SK | |||
| at outlet temperature | 190 | °C | ||
| at cooling water temperature | 20 | °C | ||
| Pump capacity/Type |
|
|||
| Flow rate max. |
|
l/min | ||
| Power consumption |
|
kW | ||
| Pressure max. |
|
bar | ||
| Control system | RT100 / RT200 | |||
| Measuring mode (standard) | Pt100 | |||
| Operating voltage | 3 x 400 V, 50/60 Hz | V/Hz | ||
| Connections | ||||
| Outlet/Inlet | G1 1/2"IG | |||
| Cooling water mains | SK / 2SK: G 1/2", 3SK: G3/4" | |||
| Degree of protection | IP54 | |||
| Dimensions W/H/D | 432/1350/1554 | mm | ||
| Weight | 250-300 | kg | ||
| Color | 9006/7016 | RAL | ||
| Ambient temperature | ||||
| max. | 40 | °C | ||
| Noise level | < 70 | db (A) |
Standard equipment
more
less
- Solid-state relay (SSR) instead of heating contactor
- Hand valve in inlet and outlet
- Water circuit of non-rusting materials
- Automatic water refill
- Filter in the main circuit
- Filter in cooling water circuit
- Leak-free pump
- Patented low-scale cooling system (SK)
- Pressure gauge outlet
- Pressure gauge for system pressure
- Unit in IP54 protection degree
- RT200 control system
Cooling curve
more
less